Our Sectors

CEMS SOX NOX & TLDS System


O2 Monitoring


Sample Handling System


Shelter Integration


Analyzer Shelters

  • Analyzers (GC, IR, UV and etc.) with the sample conditioning systems (SCS).
  • Location Classification: Zone 1 or 2; II A, IIB & IIC
  • HVAC or window air-conditioner.
  • Electrical or steam heating systems.
  • Pipe headers for instrument air, drain and/or vent.
  • Power distribution board (PDB).
  • Alarm and safety panel (ASP).
  • Horn, beacon and/or flashing warning light.
  • Gas, fire and smoke detectors.
  • Lighting fixtures.
  • Junction boxes (power, analog signal, digital signal & communication).

Analyzer Cabinet

  • Location Classification: Zone 1 or 2; II A, IIB & IIC
  • Lighting fixture
  • Pipe headers for instrument air, drain and/or vent
  • Power distribution board (PDB)
  • Alarm and safety panel (ASP)
  • Sample conditioning systems (SCS)
  • Junction boxes (JB)
  • Window air-conditioner (optional)
  • Electrical or steam heating devices (optional)

Analyzer Rack

  • Location Classification: Zone 1 or 2; II A, IIB & IIC
  • Lighting fixture
  • Pipe headers for instrument air, drain and/or vent
  • Power distribution board (PDB)
  • Alarm and safety panel (ASP)
  • Sample conditioning systems (SCS)
  • Junction boxes (JB)

Sample Recovery System

  • Location classification: Zone 1, IIA, IIB & IIC
  • Operating Temperature: up to 60 degree C
  • Tank Capacity: 100 / 200L or customized
    Wetted Material: SS304/SS316
  • Control Mode: Auto or Manual
  • Process Flow rate (Min / Normal / Max): 127 / 318 / 350 LPH
    Skid: HDG / SS304 / SS316

Sample Conditioning System

  • Location Classification: Zone 1 or 2; II A, IIB & IIC
  • Assembled on SS304/SS316 plate or housed inside an enclosure (EG/SS304/SS316) with or without insulation
  • Wall or stanchion mounting type
  • Dimension: 300W x 300H x 270D (mm) up to 800 W x 1,200H x 400D (mm) subject to components layout.

SWAS Panels

  • Location classification: Zone 1 or 2, IIB or IIC.
  • Operating Temperature: up to 60 degree C.
  • Sample Conditioning System (Wet Panel): consisting of sample lines on P&ID.
  • Manual Isolation Valve: selected for appropriate pressure and temperature.
  • High Pressure Blow down Valve: remove any particulate build up in line.
  • Primary Cooler: counter flow sample cooler. SS316 tube & SS304 shell.
  • Pressure Reducing Valve: provide proper sample flow and pressure reduction.
  • Thermal Shut-off Valve (TSV): isolate sample line at high temperature
  • Secondary Cooler: counter flow sample cooler. SS316 tube & SS304 shell
  • Pressure and Temperature Indicator: Clearly visible to operate personnel
  • Flow Indicator: proper range for particular analyzer being serviced.
  • Back Pressure Regulator: protect cell or analyzer from sample overpressure Sample Sink: grab sample facility. Analysis Module: consisting of various analyzers such Conductivity, pH, Oxygen, Hydrazine, Silica, Sodium, Phosphate & etc.
  • Control & Monitor Panel: SS304/SS316 enclosed structure, built in accordance with specification required by customer.
  • Appropriate cut-out for the instrument and components installed and rear door for access to repair or replace components inside.
  • Easy operation and maintenance. Skid: HGD / SS304 / SS316